CPKSoft Engineering

XIZUMIFA.tlk Driver Reference

Izumi FA-1/1J/2/2J Peer to Peer Protocol Driver

This driver requires that you have TAS-HMITalk 8.04 installed.

Driver Overview

XIZUMIFA driver allows you to connect to the IDEC IZUMI Corp. FA-1/FA-1J/

FA-2/FA-2J Series equipment, on a point to point basis. (there is

another extended version of the driver which allows you to connect to a

controllers network called XIZUMINT)

Supported Equipment Type

Programmable Logic Controllers

Supported Devices List

IDEC IZUMI PLC Micro-1 Series

IDEC IZUMI PLC FA-1 Series

IDEC IZUMI PLC FA-1J Series

IDEC IZUMI PLC FA-2 Series

IDEC IZUMI PLC FA-2J Series

IDEC IZUMI PLC FA-3S/CP-11 Series

IDEC IZUMI PLC FA-3S/CP-11T Series

Supported Commands List

Read I/O (Input or Output)

Read IR (Internal Relay)

Read SFR (Shift Register)

Read TIM (Timer)

Read CNT (Counter)

Read PLC (Program Error Data)

Read DR (Data Register)

Read Expansion DR

Read 10msec Timer

Read Expansion I/O

Read Expansion IR

Write TIM Preset Value

Write CNT Preset Value

Read PLC Status

Read PLC Error Data

Send PLC Error Cancel

Send Communication Cancel

Read TIM Preset Value

Read CNT Preset Value

Write I/O (Input or Output)

Write IR

Write SFR

Write Expansion I/O

Write Expansion IR

Write System Work Area

Write DR

Write Expansion DR

Read System Work Area

Read System Version

TIM/CNT Preset Value Clear

Read HSC (High Speed Counter) (FA-1 Only)

Write HST Preliminar Output 1 (FA-1 Only)

Write HST Preliminar Output 2 (FA-1 Only)

Read HST Preliminar Output 1 (FA-1 Only)

Read HST Preliminar Output 2 (FA-1 Only)

Read I/O (Input or Output)

PROPERTY SETTINGS REQUIRED:

HMITalk1.DriverDataType = Analog Input / Digital Input

HMITalk1.DriverNumPoints = Analog Input=1, Digital Input=8.

HMITalk1.DriverP0 = Not used (to maintain compatibility with XIZUMINT).

HMITalk1.DriverP1 = 1

HMITalk1.DriverP2 = Indicates the memory address of the selected element.

Read IR (Internal Relay)

PROPERTY SETTINGS REQUIRED:

HMITalk1.DriverDataType = Analog Input / Digital Input

HMITalk1.DriverNumPoints = Analog Input=1, Digital Input=8.

HMITalk1.DriverP0 = Not used (to maintain compatibility with XIZUMINT).

HMITalk1.DriverP1 = 2

HMITalk1.DriverP2 = Indicates the memory address of the selected element.

Read SFR (Shift Register)

PROPERTY SETTINGS REQUIRED:

HMITalk1.DriverDataType = Analog Input / Digital Input

HMITalk1.DriverNumPoints = Analog Input=1, Digital Input=8.

HMITalk1.DriverP0 = Not used (to maintain compatibility with XIZUMINT).

HMITalk1.DriverP1 = 3

HMITalk1.DriverP2 = Indicates the memory address of the selected element.

Read TIM (Timer)

PROPERTY SETTINGS REQUIRED:

HMITalk1.DriverDataType = Analog Input / Digital Input

HMITalk1.DriverNumPoints = Analog Input=1, Digital Input=16.

HMITalk1.DriverP0 = Not used (to maintain compatibility with XIZUMINT).

HMITalk1.DriverP1 = 4

HMITalk1.DriverP2 = Indicates the memory address of the selected element.

Read CNT (Counter)

PROPERTY SETTINGS REQUIRED:

HMITalk1.DriverDataType = Analog Input / Digital Input

HMITalk1.DriverNumPoints = Analog Input=1, Digital Input=16.

HMITalk1.DriverP0 = Not used (to maintain compatibility with XIZUMINT).

HMITalk1.DriverP1 = 5

HMITalk1.DriverP2 = Indicates the memory address of the selected element.

Read PLC (Program Error Data)

PROPERTY SETTINGS REQUIRED:

HMITalk1.DriverDataType = Analog Input / Digital Input

HMITalk1.DriverNumPoints = Analog Input=1, Digital Input=24.

HMITalk1.DriverP0 = Not used (to maintain compatibility with XIZUMINT).

HMITalk1.DriverP1 = 6

HMITalk1.DriverP2 = Indicates the memory address of the selected element.

Read DR (Data Register)

PROPERTY SETTINGS REQUIRED:

HMITalk1.DriverDataType = Analog Input / Digital Input

HMITalk1.DriverNumPoints = Analog Input=1, Digital Input=8.

HMITalk1.DriverP0 = Not used (to maintain compatibility with XIZUMINT).

HMITalk1.DriverP1 = 7

HMITalk1.DriverP2 = Indicates the memory address of the selected element.

Read Expansion DR

PROPERTY SETTINGS REQUIRED:

HMITalk1.DriverDataType = Analog Input / Digital Input

HMITalk1.DriverNumPoints = Analog Input=1, Digital Input=8.

HMITalk1.DriverP0 = Not used (to maintain compatibility with XIZUMINT).

HMITalk1.DriverP1 = 8

HMITalk1.DriverP2 = Indicates the memory address of the selected element.

Read 10msec Timer

PROPERTY SETTINGS REQUIRED:

HMITalk1.DriverDataType = Analog Input / Digital Input

HMITalk1.DriverNumPoints = Analog Input=1, Digital Input=8.

HMITalk1.DriverP0 = Not used (to maintain compatibility with XIZUMINT).

HMITalk1.DriverP1 = 9

HMITalk1.DriverP2 = Indicates the memory address of the selected element.

Read Expansion I/O

PROPERTY SETTINGS REQUIRED:

HMITalk1.DriverDataType = Analog Input / Digital Input

HMITalk1.DriverNumPoints = Analog Input=1, Digital Input=8.

HMITalk1.DriverP0 = Not used (to maintain compatibility with XIZUMINT).

HMITalk1.DriverP1 = 10

HMITalk1.DriverP2 = Indicates the memory address of the selected element.

Read Expansion IR

PROPERTY SETTINGS REQUIRED:

HMITalk1.DriverDataType = Analog Input / Digital Input

HMITalk1.DriverNumPoints = Analog Input=1, Digital Input=8.

HMITalk1.DriverP0 = Not used (to maintain compatibility with XIZUMINT).

HMITalk1.DriverP1 = 11

HMITalk1.DriverP2 = Indicates the memory address of the selected element.

Write TIM Preset Value

PROPERTY SETTINGS REQUIRED:

HMITalk1.DriverDataType = Analog Output / Digital Output

HMITalk1.DriverNumPoints = Analog Output=1, Digital Output=16.

HMITalk1.DriverP0 = Not used (to maintain compatibility with XIZUMINT).

HMITalk1.DriverP1 = 12

HMITalk1.DriverP2 = Indicates the memory address of the selected element.

Write CNT Preset Value

PROPERTY SETTINGS REQUIRED:

HMITalk1.DriverDataType = Analog Output / Digital Output

HMITalk1.DriverNumPoints = Analog Output=1, Digital Output=16.

HMITalk1.DriverP0 = Not used (to maintain compatibility with XIZUMINT).

HMITalk1.DriverP1 = 13

HMITalk1.DriverP2 = Indicates the memory address of the selected element.

Read PLC Status

PROPERTY SETTINGS REQUIRED:

HMITalk1.DriverDataType = Analog Input / Digital Input

HMITalk1.DriverNumPoints = Analog Input=1, Digital Input=32.

HMITalk1.DriverP0 = Not used (to maintain compatibility with XIZUMINT).

HMITalk1.DriverP1 = 14

HMITalk1.DriverP2 = Indicates the memory address of the selected element.

Read PLC Error Data

PROPERTY SETTINGS REQUIRED:

HMITalk1.DriverDataType = Analog Input / Digital Input

HMITalk1.DriverNumPoints = Analog Input=1, Digital Input=32.

HMITalk1.DriverP0 = Not used (to maintain compatibility with XIZUMINT).

HMITalk1.DriverP1 = 15

HMITalk1.DriverP2 = Indicates the memory address of the selected element.

Send PLC Error Cancel

PROPERTY SETTINGS REQUIRED:

HMITalk1.DriverDataType = Analog Output / Digital Output

HMITalk1.DriverNumPoints = Analog Output=1, Digital Output=32.

HMITalk1.DriverP0 = Not used (to maintain compatibility with XIZUMINT).

HMITalk1.DriverP1 = 16

HMITalk1.DriverP2 = Indicates the memory address of the selected element.

Send Communication Cancel

PROPERTY SETTINGS REQUIRED:

HMITalk1.DriverDataType = Analog Output / Digital Output

HMITalk1.DriverNumPoints = Analog Output=1, Digital Output=32.

HMITalk1.DriverP0 = Not used (to maintain compatibility with XIZUMINT).

HMITalk1.DriverP1 = 17

HMITalk1.DriverP2 = Indicates the memory address of the selected element.

Read TIM Preset Value

PROPERTY SETTINGS REQUIRED:

HMITalk1.DriverDataType = Analog Input / Digital Input

HMITalk1.DriverNumPoints = Analog Input=1, Digital Input=16.

HMITalk1.DriverP0 = Not used (to maintain compatibility with XIZUMINT).

HMITalk1.DriverP1 = 18

HMITalk1.DriverP2 = Indicates the memory address of the selected element.

Read CNT Preset Value

PROPERTY SETTINGS REQUIRED:

HMITalk1.DriverDataType = Analog Input / Digital Input

HMITalk1.DriverNumPoints = Analog Input=1, Digital Input=16.

HMITalk1.DriverP0 = Not used (to maintain compatibility with XIZUMINT).

HMITalk1.DriverP1 = 19

HMITalk1.DriverP2 = Indicates the memory address of the selected element.

Write I/O (Input or Output)

PROPERTY SETTINGS REQUIRED:

HMITalk1.DriverDataType = Analog Output / Digital Output

HMITalk1.DriverNumPoints = Analog Output=1, Digital Output=8.

HMITalk1.DriverP0 = Not used (to maintain compatibility with XIZUMINT).

HMITalk1.DriverP1 = 20

HMITalk1.DriverP2 = Indicates the memory address of the selected element.

Write IR

PROPERTY SETTINGS REQUIRED:

HMITalk1.DriverDataType = Analog Output / Digital Output

HMITalk1.DriverNumPoints = Analog Output=1, Digital Output=8.

HMITalk1.DriverP0 = Not used (to maintain compatibility with XIZUMINT).

HMITalk1.DriverP1 = 21

HMITalk1.DriverP2 = Indicates the memory address of the selected element.

Write SFR

PROPERTY SETTINGS REQUIRED:

HMITalk1.DriverDataType = Analog Output / Digital Output

HMITalk1.DriverNumPoints = Analog Output=1, Digital Output=8.

HMITalk1.DriverP0 = Not used (to maintain compatibility with XIZUMINT).

HMITalk1.DriverP1 = 22

HMITalk1.DriverP2 = Indicates the memory address of the selected element.

Write Expansion I/O

PROPERTY SETTINGS REQUIRED:

HMITalk1.DriverDataType = Analog Output / Digital Output

HMITalk1.DriverNumPoints = Analog Output=1, Digital Output=1.

HMITalk1.DriverP0 = Not used (to maintain compatibility with XIZUMINT).

HMITalk1.DriverP1 = 23

HMITalk1.DriverP2 = Indicates the memory address of the selected element.

Write Expansion IR

PROPERTY SETTINGS REQUIRED:

HMITalk1.DriverDataType = Analog Output / Digital Output

HMITalk1.DriverNumPoints = Analog Output=1, Digital Output=1.

HMITalk1.DriverP0 = Not used (to maintain compatibility with XIZUMINT).

HMITalk1.DriverP1 = 24

HMITalk1.DriverP2 = Indicates the memory address of the selected element.

Write System Work Area

PROPERTY SETTINGS REQUIRED:

HMITalk1.DriverDataType = Analog Output / Digital Output

HMITalk1.DriverNumPoints = Analog Output=1, Digital Output=8.

HMITalk1.DriverP0 = Not used (to maintain compatibility with XIZUMINT).

HMITalk1.DriverP1 = 25

HMITalk1.DriverP2 = Indicates the memory address of the selected element.

Write DR

PROPERTY SETTINGS REQUIRED:

HMITalk1.DriverDataType = Analog Output / Digital Output

HMITalk1.DriverNumPoints = Analog Output=1, Digital Output=32.

HMITalk1.DriverP0 = Not used (to maintain compatibility with XIZUMINT).

HMITalk1.DriverP1 = 27

HMITalk1.DriverP2 = Indicates the memory address of the selected element.

Write Expansion DR

PROPERTY SETTINGS REQUIRED:

HMITalk1.DriverDataType = Analog Output / Digital Output

HMITalk1.DriverNumPoints = Analog Output=1, Digital Output=32.

HMITalk1.DriverP0 = Not used (to maintain compatibility with XIZUMINT).

HMITalk1.DriverP1 = 28

HMITalk1.DriverP2 = Indicates the memory address of the selected element.

Read System Work Area

PROPERTY SETTINGS REQUIRED:

HMITalk1.DriverDataType = Analog Input / Digital Input

HMITalk1.DriverNumPoints = Analog Input=1, Digital Input=8.

HMITalk1.DriverP0 = Not used (to maintain compatibility with XIZUMINT).

HMITalk1.DriverP1 = 30

HMITalk1.DriverP2 = Indicates the memory address of the selected element.

Read System Version

PROPERTY SETTINGS REQUIRED:

HMITalk1.DriverDataType = Analog Input / Digital Input

HMITalk1.DriverNumPoints = Analog Input=1, Digital Input=24.

HMITalk1.DriverP0 = Not used (to maintain compatibility with XIZUMINT).

HMITalk1.DriverP1 = 33

HMITalk1.DriverP2 = Indicates the memory address of the selected element.

TIM/CNT Preset Value Clear

PROPERTY SETTINGS REQUIRED:

HMITalk1.DriverDataType = Analog Output / Digital Output

HMITalk1.DriverNumPoints = Analog Output=1, Digital Output=16.

HMITalk1.DriverP0 = Not used (to maintain compatibility with XIZUMINT).

HMITalk1.DriverP1 = 34

HMITalk1.DriverP2 = Indicates the memory address of the selected element.

Read HSC (High Speed Counter) (FA-1 Only)

PROPERTY SETTINGS REQUIRED:

HMITalk1.DriverDataType = Analog Input / Digital Input

HMITalk1.DriverNumPoints = Analog Input=1, Digital Input=32.

HMITalk1.DriverP0 = Not used (to maintain compatibility with XIZUMINT).

HMITalk1.DriverP1 = 35

HMITalk1.DriverP2 = Indicates the memory address of the selected element.

Write HST Preliminar Output 1 (FA-1 Only)

PROPERTY SETTINGS REQUIRED:

HMITalk1.DriverDataType = Analog Output / Digital Output

HMITalk1.DriverNumPoints = Analog Output=1, Digital Output=32.

HMITalk1.DriverP0 = Not used (to maintain compatibility with XIZUMINT).

HMITalk1.DriverP1 = 36

HMITalk1.DriverP2 = Indicates the memory address of the selected element.

Write HST Preliminar Output 2 (FA-1 Only)

PROPERTY SETTINGS REQUIRED:

HMITalk1.DriverDataType = Analog Output / Digital Output

HMITalk1.DriverNumPoints = Analog Output=1, Digital Output=32.

HMITalk1.DriverP0 = Not used (to maintain compatibility with XIZUMINT).

HMITalk1.DriverP1 = 37

HMITalk1.DriverP2 = Indicates the memory address of the selected element.

Read HST Preliminar Output 1 (FA-1 Only)

PROPERTY SETTINGS REQUIRED:

HMITalk1.DriverDataType = Analog Input / Digital Input

HMITalk1.DriverNumPoints = Analog Input=1, Digital Input=32.

HMITalk1.DriverP0 = Not used (to maintain compatibility with XIZUMINT).

HMITalk1.DriverP1 = 38

HMITalk1.DriverP2 = Indicates the memory address of the selected element.

Read HST Preliminar Output 2 (FA-1 Only)

PROPERTY SETTINGS REQUIRED:

HMITalk1.DriverDataType = Analog Input / Digital Input

HMITalk1.DriverNumPoints = Analog Input=1, Digital Input=32.

HMITalk1.DriverP0 = Not used (to maintain compatibility with XIZUMINT).

HMITalk1.DriverP1 = 39

HMITalk1.DriverP2 = Indicates the memory address of the selected element.

Returned Errors List

[1005] DRIVER (Internal): Invalid driver stage

[1300] PROTOCOL (Timeout): No answer

[1419] PROTOCOL (Format): Missing bytes in response

[1429] PROTOCOL (Format): Unknown response

[2209] CONFIG (NumValues): Too many values (max=32)

[3508] CONFIG (P1): Invalid command

[4001] CONFIG (P2): Invalid address

[8002] CONFIG (Remote): Abnormal receive command (receive error)

[8279] CONFIG (Remote): Program transfer/write Overtime/frame error

[8280] CONFIG (Remote): Program transfer/write Read/write error

[8281] CONFIG (Remote): Program transfer/write ROM pack

[8282] CONFIG (Remote): Program transfer/write TOTAL

[8290] CONFIG (Remote): Receive data over (PLC size error)

[8291] CONFIG (Remote): Receive inhibit (PLC run error)

[8347] CONFIG (Remote): Unknown error

About the XIZUMIFA.tlk driver

This driver requires that you have TAS-HMITalk 8.04 installed.

Driver Source Code Last Update: 03/08/2004 14:07:26