Register :: Login 
   
 February 5, 2012  
Communication drivers Minimize
All our drivers can be used with any of the following configurations:
Drivers de comunicación
All our drivers can be used with any of the following configurations:
Drivers de comunicación
 
More links... Minimize
 
Your cart contents Your cart contents Minimize
Product Qty. Price
TOTAL: 0 0.00 USD
 
Popular products Minimize
See details... XMODBTCP Modbus TCP Protocol Drive...
See details... XALSTOM Areva Alstom IEC 87...
See details... XMODBUSB Gould Modicon Modbu...
See details... XS7PPI Siemens S7-200 Advanced...
See details... XELVIPD3 ElControl Energy VIPD3-485...
See details... GetPCId.exe Utility for collecting...
See details... XADAM Advantech Adam Series...
See details... XNAIS NAIS Matsushita MEWTOCOL-COM...
See details... XWIMPACC Westinghouse IMPACC System...
See details... XCVENETA ClimaVeneta CVM300-3000...
See details... XIGPL100 IG Instrumentos DataLogger...
See details... XCONDENS System Electric Condensomatic...
See details... XHART Rosemount Hart Revision...
See details... XALGODUE Algodue UPM Series Universal...
See details... XGECALST Gec Alsthom Addressable...
See details... XHITACHH Hitachi PLC Serie H Protocol...
See details... XABF Allen Bradley Full Duplex...
 
 Drivers   
List of drivers in TAS-HMITalk 8.04 (some are not included in the standard license) Minimize
Let us know if you need help to create a specific example to test your device with any of our drivers or if you need that we develop a new driver to communicate with your field equipment. In order to test a driver you have to download the TAS-HMITalk activex component. After unzipping the zip file, be sure to register the hmitalk.ocx with regsvr32.exe. There is aditional information about TAS-HMITalk in our support blog. To open any example you will need Visual Basic 6.0. To write new applications we suggest that yo use Visual Studio Express.Net 2008 which is a free programming tool that can be downloaded at http://www.msdn.com.
Let us know if you need help to create a specific example to test your device with any of our drivers or if you need that we develop a new driver to communicate with your field equipment. In order to test a driver you have to download the TAS-HMITalk activex component. After unzipping the zip file, be sure to register the hmitalk.ocx with regsvr32.exe. There is aditional information about TAS-HMITalk in our support blog. To open any example you will need Visual Basic 6.0. To write new applications we suggest that yo use Visual Studio Express.Net 2008 which is a free programming tool that can be downloaded at http://www.msdn.com.
 
XKOYO305 Driver - Koyo DL305 PLC Family Communications Driver
This driver is included with all unlimited licenses of TAS-HMITalk. It is not sold separately. It can be used to communicate through a physical serial COM port, through a virtual COM port or through an IP port in serial-over-IP configuration.

If you think that this driver could talk to your device, you can test it by downloading a trial version of TAS-HMITalk, where you will find examples about how to configure the activex to use it with different drivers. Consider that this driver might also support some devices that are not listed in the Supported Devices list below but that can talk using the same protocol.
You can also hire our services to modify this driver, to expand its current functionallity or to develop a new driver based on it.
If you have any doubt about this driver, do not hesitate to contact us.

Driver Manual:
- Download the driver manual in Adobe Acrobat PDF format here: XKOYO305.pdf
- Download the driver manual in HTML format here: XKOYO305.htm

Driver Source Code:

Source-code files for this driver are available in plain-C language for additional USD299 with your purchase of the Unlimited License of TAS-HMITalk for 500 object instances.

Driver details:

XKOYO305 driver allows you to connect to KOYO Direct PLCs, Series 305, using DirectNet (hexa-mode) protocol.


Supported devices

This driver can communicate with these devices, but is not necessarily limited to this list:

  • KOYO Direct Logic DL305 Series

  • KOYO Direct Logic DL330 PLC

  • KOYO Direct Logic DL330P PLC

  • KOYO Direct Logic DL340 PLC


  • Command list

    This driver supports the following commands. If you need to implement some other command that is not included in this list, please let us know.

  • Read Timer/Counter/Data Registers in Binary Mode

  • Read Input/Output, Internal Relays and Shift Register Bits in Words and Binary Mode

  • Read Scratch Pad Memory in Binary Mode

  • Read Ladder Memory in Binary Mode

  • Read Communication Errors in Binary Mode

  • Read Input/Output, Internal Relays and Shift Register Bits in Bit Mode

  • Write Timer/Counter/Data Registers in Binary Mode

  • Write Input/Output, Internal Relays and Shift Register Bits in Words and Binary Mode

  • Write Scratch Pad Memory in Binary Mode

  • Write Ladder Memory in Binary Mode

  • Write Communication Errors in Binary Mode

  • Write Input/Output, Internal Relays and Shift Register Bits in Bit Mode

  • Read Timer/Counter/Data Registers in BCD Mode

  • Read Input/Output, Internal Relays and Shift Register Bits in Words and BCD Mode

  • Read Scratch Pad Memory in BCD Mode

  • Read Ladder Memory in BCD Mode

  • Read Communication Errors in BCD Mode

  • Write Timer/Counter/Data Registers in BCD Mode

  • Write Input/Output, Internal Relays and Shift Register Bits in Words and BCD Mode

  • Write Scratch Pad Memory in BCD Mode

  • Write Ladder Memory in BCD Mode

  • Write Communication Errors in BCD Mode


  • See also:

    ActiveX - CPKSoft Engineering - TAS-HMITalk 8.04 Unlimited License for up to 5 object instances
    ActiveX - CPKSoft Engineering - TAS-HMITalk 8.04 Unlimited License for up to 50 object instances
    ActiveX - CPKSoft Engineering - TAS-HMITalk 8.04 Unlimited License for up to 500 object instances
    Utility - CPKSoft Engineering - GetPCId.exe



     
    See all drivers

    New entries in our support blog Minimize
    Author: CPKSoft Engineering Support Created: 5/26/2008 11:10 AM
    Answers to technical questions about TAS-HMITalk made by customers and registered users.

    I cannot register hmitalk.ocx in Windows Vista
    By CPKSoft Engineering Support on 3/18/2009 3:31 PM

    Some users have reported problems when registering the hmitalk.ocx file under Windows Vista. We have found that the solution to this is running the registration tool as Administrator.

    For example, if you use VB5 or VB6 to register the ocx (by adding it to the toolbox using the rigth-click menu), make sure to launch the VB exe file with the "Run as Administrator" option.

    With Visual Basic.Net 2008 Express, we have found that it is not necessary to run it as administrator.

    We have found problems to register the ocx correctly with regsvr32.exe under Windows Vista, so we recommend that you use VB5, VB6, VB.Net 2008 or the development environment that you are using in order to register the ocx. Recently we have included an utility named RegHMITalk.exe that registers the ocx correctly in your Vista system.



    Comments (7)

    Quick steps to install TAS-HMITalk
    By CPKSoft Engineering Support on 11/22/2008 6:34 PM

    To install TAS-HMITalk in your machine follow these steps:

    - Download the TAS-HMITalk distribution .zip file from http://www.cpksoft.com.
    - Extract the .zip file contents to a local folder.
    - Locate the hmitalk.ocx file, right-click over it and select "Open with...".
    - Browse to 'C:\Windows\System32' and select 'regsvr32.exe' and Accept.
    - The ocx file should now be registered by Windows in your machine.
    - Repeat the same steps with linechrt.ocx and grid32.ocx.
    - Now you can add TAS-HMITalk to your Visual Basic toolbox and/or open the examples.



    Comments (11)

    New TriggerAndWait method
    By CPKSoft Engineering Support on 10/2/2008 6:46 PM

    A new method called TriggerAndWait has been added to the TAS-HMITalk activex. This method triggers a new communication and then blocks the execution of the application thread until the communication has finished. This way it is easier to implement a communication strategy where several TAS-HMITalk objects must be cascaded in a particular order.
     
    Following is an example of a routine to handle a button event in an application written in C# with Visual Studio 2005 that reads data from a relay:
     
    private void button1_Click(object sender, EventArgs e)
    {
              & ... Read More »

    Comments (11)

    What cable should I use to connect TAS-HMITalk to my Siemens S7-200 PLCs?
    By CPKSoft Engineering Support on 8/12/2008 5:56 PM

    The xs7ppi.tlk driver was successfully tested in several applications with PLCs belonging to the S7-200 family using the following cable:

    - Cable PC/PPI multimaster
    - 6ES7 901-3CB30-0XA0
    - E-STAND:03

    This cable can be ordered to Siemens as follows:

    Smart RS232/PPI cable with built-in RS232/RS485 level converter (6ES7 901-3CB30-0XA0)

    Suggested Cable Dip Switches Configuration: Read More »

    Comments (20)

    How can I get connected to my devices with TAS-HMITalk?
    By CPKSoft Engineering Support on 7/21/2008 7:23 PM

    TAS-HMITalk and any of its drivers can be used in any of the following configurations, with direct RS-232 connections, connections through RS-232/485 converters, connections through ethernet/serial converters, connections through virtual serial ports, etc.:

    Drivers de comunicación



    Comments (8)

    MOXA Serial-to-Ethernet NPort 6150 module tested wiith TAS-HMITalk
    By CPKSoft Engineering Support on 6/1/2008 6:06 PM

    Last week we had the chance to test the Moxa NPort 6150 Secure Serial Port Server Module with TAS-HMITalk to communicate with the serial port of a DanLoad 6000 electronic preset through the ethernet LAN at a fertilizer plant from Petrobras in Campana, Argentina.

    The Moxa device was provided by RCL Systems, a company specialized in integrating InTouch factory suite applications for oil&gas industries.

    The loopback tests worked great, showing that TAS-HMITalk could talk to the MOXA module directly, without the need of installing any COM port redirector software. TAS-HMITalk could properly recover from our intentionally-caused communication errors, such as cable disconnections and module power-off and on.

    The DanLoad 6000 didn ... Read More »

    Comments (10)

    Comments about sending outputs
    By CPKSoft Engineering Support on 5/26/2008 8:59 PM

    1. Configure your HMITalk object properties according to what the driver help file says for the chosen driver and command. Leave default values for properties not mentioned in the help file.
    2. Leave the ScanActive=False and uncheck the ScanAutoTrigger property.
    3. Create a Button to send the data
    4. In the Button_Click event, place this code:
       HMITalkxxx.PointValue(0) = <the value to be sent>
       HMITalkxxx.Trigger ' To dispatch the writing action
    5. Then just listen to the OnSuccessfullySent event or the OnErrorSending event.


    Comments (20)

    Example configuring a Modbus RTU communication
    By CPKSoft Engineering Support on 5/26/2008 8:50 PM

    All drivers are configured using the same set of properties DriverP0 to DriverP9 and the meaning of these properties changes from one driver to other.

    For example, to read a register value at address D0000 from a device supporting Modbus RTU, you should configure one TAS-HMITalk object as follows:
     
    DriverName = “XModbusb”
    DriverDataType = Analog_Input (because you will be reading words this time)
    DriverNumPoints = 1 or whatever number ob registers you want to read (up to 125)
    DriverP0 = PLC station number (project1.exe uses 1, which seemed to work OK)
    DriverP1 = 3 or 4, depending on what your PLC supports.
    DriverP2 = the starting address to be read (32768 for D0000)
    DriverP3 to DriverP9 are not used for this case.
     
    If you want the HMITalk object to periodically read your device, you don't need to call the .Trigger method each time. Y ... Read More »

    Comments (26)

    Periodic reading vs. On-demand reading
    By CPKSoft Engineering Support on 5/26/2008 8:38 PM

    The best approach to read data on a periodic basis is:

    1. Set the ScanActive to True
    2. Let the OnSuccessfullyReceived event or the OnPointValueChanged events do the work for you.

    The best approach for on-demand reading is:

    1. Call the Trigger method
    2. Again, let the OnSuccessfullyReceived event or the OnPointValueChanged events do the work for you.


    Comments (6)

    Comments about configuring a PID loop
    By CPKSoft Engineering Support on 5/26/2008 8:33 PM

    1. To build a closed PID loop, you will need two TAS objects. One to read the process variable and the other to send the control signal back to the plant.
    2. Only the TAS object that is reading the process variable needs to have its PID properties set. The TAS object which sends the output is configured as you do with any other normal TAS object.
    3. The EnablePIDs TAS general property must be True for PIDs to operate.
    4. You will need to devote one PointValue for each PID loop you need.
    5. The PointPIDEnable property of that point must be set to True
    6. As a minimun, the PointPIDSetpoint, PointPIDKp, PointPIDKi and PointPIDKd must be set to appropriate values.
    7. The PointPIDLowPhysic and PointPIDHighPhysic properties will scale the control signal between 0% and 100%.
    8. The value of the control signal generated by the PID algor ... Read More »

    Comments (11)

     
    New entries in our support blog Minimize
     
    Available licenses Minimize
    See details and download trial...
    399.00 USD
    Unlimited license to build applications with Visual Basic that...
    See more...
    See details and download trial...
    899.00 USD
    Unlimited license to build applications with Visual Basic that...
    See more...
    See details and download trial...
    1,399.00 USD
    Unlimited license to build applications with Visual Basic that...
    See more...
     
    Available drivers Minimize
    See details... XABF Allen Bradley Full Duplex...
    See details... XABH Allen Bradley Half Duplex...
    See details... XABSLC5 Allen Bradley SLC-500...
    See details... XACROMAG Acromag Series 4600 I/O...
    See details... XADAM Advantech Adam Series...
    See details... XAFEISA Afeisa Industrial Microcomputers...
    See details... XAIBUS Yudian AI-BUS Protocol...
    See details... XALGODUE Algodue UPM Series Universal...
    See details... XALSTOM Areva Alstom IEC 87...
    See details... XAND4325 AND AD-4325V Weight Indicator...
    See details... XARCOMA Arcom M1 Modbus Ascii...
    See details... XARCOMB Arcom M1 Modbus RTU Protocol...
    See details... XBCOLMAN Barber Colman model MAQ...
    See details... XCAMMESA Driver for collecting...
    See details... XCATM5X Caterpillar CCM/M5X Protocol...
    See details... XCEWE Cewe Instruments Using...
    See details... XCONDENS System Electric Condensomatic...
    See details... XCOOPER Cooper Power System...
    See details... XCORSAN IG Instrumentos CORSAN...
    See details... XCVENETA ClimaVeneta CVM300-3000...
    See details... XCVMBDM Circutor CVM-BD Memory...
    See details... XCVMITF Circutor CVM-ITF/CVM-R8C...
    See details... XCVMMEM Circutor CVM-M Memory...
    See details... XCVMMOD Circutor CVM-BD-M Modbus...
    See details... XCYBELEC Cybelec DNC-20 Protocol...
    See details... XDANIELA Daniel Industries Devices...
    See details... XDANLOAD Emerson Daniel DanLoad...
    See details... XDLXVIP Algodue Elettronica DLX...
    See details... XDUCATI Ducati Mach-Smart Analyzer...
    See details... XDX9100 Johnson Controls Metasys...
    See details... XELVIPD3 ElControl Energy VIPD3-485...
    See details... XELVIPEN ElControl VIP Energ...
    See details... XEXEMYS Exemys SSE232 Serial/Ethernet...
    See details... XFOX760 Foxboro 760CNA/760CSA...
    See details... XFOX761 Foxboro 761CNA/761CSA...
    See details... XFOX762 Foxboro 762C/762CSA/743CB...
    See details... XGATECIT Gatecit Additive Injectors...
    See details... XGAVAZZI Carlo GAVAZZI Instruments...
    See details... XGECALST Gec Alsthom Addressable...
    See details... XGEFAN90 GE Fanuc Series 90 SNP-X...
    See details... XGEMLINK General Electric M-LINK...
    See details... XGLOBALW Global Weighing MP 30...
    See details... XHART Rosemount Hart Revision...
    See details... XHITACHE Hitachi PLCs EB/EC/EM-II...
    See details... XHITACHH Hitachi PLC Serie H Protocol...
    See details... XHITAS10 Hitachi HIDIC S10 Alpha...
    See details... XIDECM3 Idec Izumi Micro3 Programmable...
    See details... XIDECONC Idec Open Net Controller...
    See details... XIEARING IEA Single-Loop Controllers...
    See details... XIGDL2CH IG Instrumentos DataLogger...
    See details... XIGEVAPO IG Instrumentos Evaporimeter...
    See details... XIGPL100 IG Instrumentos DataLogger...
    See details... XINTERGY Swichtec SM20/Sm50 Intergy...
    See details... XIZUMFA3 Izumi FA-3S/FA2-5M Communication...
    See details... XIZUMIFA Izumi FA-1/1J/2/2J Peer...
    See details... XIZUMINT Izumi FA-1/1J/2/2J Network...
    See details... XKMOELLR Hitachi PLC Serie H Protocol...
    See details... XKOYO305 Koyo DL305 PLC Family...
    See details... XKOYO405 Koyo DL405 PLC Family...
    See details... XLENNOX Lennox IMC System Bus...
    See details... XLOGNET Tecnotrol LogicNET Communication...
    See details... XMBENRON Modbus Enron ASCII Protocol...
    See details... XMELSECA Mitsubishi Melsec-Q A-Compatible...
    See details... XMITSUFX Mitsubishi PLC FX Series...
    See details... XMODBTCP Modbus TCP Protocol Drive...
    See details... XMODBUSA Gould Modicon Modbu...
    See details... XMODBUSB Gould Modicon Modbu...
    See details... XMODEM Hayes Compatible Modem...
    See details... XN2 Johnson Controls N2 Master...
    See details... XNAIS NAIS Matsushita MEWTOCOL-COM...
    See details... XND601X ADLink Technology NuDAM-601X...
    See details... XOMRON Omron Sysmac C20H/C28H/C40H...
    See details... XOPTOMUX Opto22 I/O Optomux Modules...
    See details... XPOW3300 Power Measurement 3300...
    See details... XPOW3710 Power Measurement 3710...
    See details... XPOW3720 Power Measurement 3720...
    See details... XPOW6200 Power Measurement 6200...
    See details... XPOW7300 Power Measurement 7300/7330...
    See details... XPROT200 ABB Procontic T-200 Protocol...
    See details... XREDLION Red Lion Counters Protocol...
    See details... XRIAC Micro Axial RIAC Remote...
    See details... XROC300 Fisher Controls ROC300...
    See details... XS5CP521 Siemens S5-90U/95U/100U...
    See details... XS5CP524 Siemens S5-115U/135U/150U...
    See details... XS7MPI Siemens S7-300/400 MPI...
    See details... XS7MPITP Siemens S7-300/400 MPI...
    See details... XS7PPI Siemens S7-200 Advanced...
    See details... XSAIADAT Saia PCD3 Series S-BUS...
    See details... XSAIAPCD Saia PCD Series Point...
    See details... XSAIASS0 Saia PCD Series S-BUS...
    See details... XSAMCPU2 Samsung FARA PLC CP...
    See details... XSAMSECT Samsung SECTOCOL-COM/N70/N700...
    See details... XSCD80 Caipe SCD 80 Programmable...
    See details... XSHISD20 Shimaden SD20 Serie...
    See details... XSHISR50 Shimaden SR50 Serie...
    See details... XSIM4100 Simplex 4100 Fire Alarm...
    See details... XSIXNET SixNet GTU Protocol Drive...
    See details... XSQUARED Square-D SY/MAX Point-to-Point...
    See details... XSUCOMA Klockner-Moeller SUCOM-A...
    See details... XSYLVAC Sylvac Measuring Instruments...
    See details... XTEST Serial Line Testing Master...
    See details... XTIS305 Texas Instruments TI-305...
    See details... XTIS405 Texas Instruments TI-405...
    See details... XTIS505 Texas Instruments TI-505...
    See details... XTIS505T Texas Instruments TI-505...
    See details... XTSXNANO Telemecanique TSX Nano...
    See details... XTWIDOS Schneider Electric Telemecanique...
    See details... XTWIDOT Schneider Electric Telemecanique...
    See details... XTXM IG Instrumentos TECPET/MNT...
    See details... XUDC3000 Honeywell UDC 3000 Universal...
    See details... XUDC9000 Honeywell UDC9000 Controllers...
    See details... XUMC600 Umc600 Weight Indicator...
    See details... XVILTER Vilter Compressors Protocol...
    See details... XWIMPACC Westinghouse IMPACC System...
    See details... XWITNET WIT-NET TRSII v4.7 Protocol...
    See details... XYOKOUT Yokowaga UT35/UT15/UM05...
    See details... XYOKUT37 Yokogawa UT37/UT38 Controller...
    See details... XYUYAO Yuyao Changjiang Temperature...
    See details... XZET173X Zetron M173X Controller...
    See details... XZETMODB Zetron M1708/1716 Modbus...
    See details... XZETRON Zetron M1700 Controller...
     
     Copyright 1990-2008 by CPKSoft   Terms Of Use  Privacy Statement