XAND4325: AND AD-4325V Weight Indicator Protocol Driver v10.0


XAND4325: AND AD-4325V Weight Indicator Protocol Driver

General Information:


XAND4325 allows you to connect to the AAndD COMPANY Ltd., AD-4325V weighing indicator scales.

CONFIGURATION:

In order to configure parameters related to the scale communication, the following steps must be followed:
  • 1) Press STND\OPR. The display must be turned on.

  • 2) Open the front panel cover where the Dip-Switch are.

  • 3) Turn the Dip-Switch S3 ON. "Func" should be displayed and a "01" should blink on the setpoint display.

  • 4) Using the keys "<", ">", "+" and "-" select the number of the function to be changed and hit "ENTER". A 0 should blink on the final weight display.

  • 5) Use keys "+" and "-" to enter the desired value. Then hit "ENTER" to set the value.

  • 6) Once the configuration is ready, change the Dip-Switch S3 to OFF. "END" should be displayed.


  • The following are the functions to configure:

    F41 - WXYZ combined parameter, where

  • W = Indicates Baud Rate (2-1200 Bauds, 3-2400 Bauds, 4-4800 Bauds or 5-9600 Bauds)

  • X = Indicates data Bits and Stop Bits

  • 0 = 7 Data bits and 1 Stop bit

  • 1 = 7 Data bits and 2 Stop bit

  • 2 = 8 Data bits and 1 Stop bit

  • 3 = 8 Data bits and 2 Stop bit

  • Y = Indicates Parity (0-Even, 1-Odd or 2-No Parity)

  • Z = End of message (zero must be set,i.e. CR+LF)

  • F42 - Output Data

  • 1 = Sends the same displayed information

  • 2 = GROSS Data

  • 3 = NET Data

  • 4 = TARE Data

  • F43 - Output Mode Must be set on option 5 (Command Mode #2)

    F44 - Output Availability Must be set on option 1 (Always available)

    F45 - Output Format Must be set on option 1 (Sending with SP Code Number)

    F46 - Communication Mode Must be set on option 2 (Sending with Address)

    F47 - Address Number A number from 0 to 9 may be set.


    Available Commands:



    Supported Devices:

    (This list is only indicative and may exist other unlisted equipment that are also communicable with this driver).


    This driver includes:



    Available Downloads:



    To purchase a license please contact Engineering CPKSoft to any of our contact options.
    Return to All Drivers
    Licenses

    The licenses of all our drivers are unlimited in terms of the number of machines where they can be used, the number of I/O that can read or written, and the number of components that can be included in each application.

    After purchasing a license, the owner can use the driver and all its components to assemble and distribute as many applications to as many users as needed.

    The license owner retains full control of his applications by deciding himself what target machines can they be run at. For this, each driver is provided with two runtime license management tools: GetPCId.exe and MakeLic.exe.